Rant: a senior guy at a training in Fort Worth showed me why my crimps kept failing on the drop ceiling runs | Cable Installers - The Design Community Hub
Rant: a senior guy at a training in Fort Worth showed me why my crimps kept failing on the drop ceiling runs
Spent 2 days at a certification class in Fort Worth last month and figured I already knew everything about terminating. Half hour in, this old guy watches me crimp a connector and tells me I'm squeezing the tool too slow. Says a slow squeeze lets the pin shift before it seats. I switched to one quick firm press and my fail rate on the next 40 test fittings dropped to nothing. Never would've guessed speed mattered that much. Any of you get told something like that on the job that stuck with you?