Ran a 2 minute exit delay on a bet and the homeowner beat the keypad twice
A buddy said 30 seconds was plenty for his garage door, so I set his entry delay to 2 minutes just to prove a point, and his kid managed to arm, disarm, and arm again before the chime finished. Turns out the delay was never the problem, his door contact was mounted 4 inches off the magnet and dropping the zone every few days. What's the longest entry delay you'll put on a keypad before you start asking about the door itself?
4 inches off the magnet is basically a zone that's been lying to him for weeks. That gap gets worse with heat and door sag, so the panel sees an open then a close in a split second and starts the exit timer all over again. I've seen a 45 second delay feel like 3 minutes because the contact kept tripping and resetting the count. Before I'd go past 60 seconds on an entry delay I want a meter on the loop and a look at the gap, not a longer timer.