Spent a whole afternoon trying to fix a leaky tube sheet on a condenser

I was re-tubing an old condenser at a chemical plant outside Baton Rouge last month. Got the new tubes in, expanded them, pressure test showed a slow weep on three tubes. Took me from lunch to almost quitting time to figure out I had a bad tube sheet - pitting I missed on the initial inspection. Any of y'all run into hidden damage like that that ate up your whole day?
2 comments

Log in to join the discussion

Log In
2 Comments
the_patricia
Read an article in Chemical Processing last month that said roughly 30% of tube sheet failures get missed on first look because the pitting hides under old tube stubs. @riley517, sometimes you gotta pull the old tubes and clean the sheet before you can see what's really there.
8
riley517
riley5177d ago
idk, maybe you just weren't looking hard enough the first time. a good visual inspection should've caught that pitting before you even started re-tubing. sounds like you were rushing through the prep work to me.
6